- 关于我们
- 数据网络
- 通信基础设施
- 产品
-
资源中心
- 资源中心
- 文件中心
- Blog
-
成功案例
- Overview
- Innoasis development in Norway
- Eemsdelta Campus
- Hotelschool The Hague
- Emergency covid hospital, Hong Kong
- Société du Grand Paris
- Centrin Datacentres
- Airbus
- Athens Historic City Hall
- Pinewood Studios
- Goethe University Frankfurt
- Denmark New University Hospital
- 图卢兹大学
- CHM Maubeuge: a model for future-ready hospitals
- 英文博客
- 软件工具
- 质保
- 新闻及动态
- 查找
- 联系我们
- Compare
- 登录
LANmark-OF ENSPACE Method B MTP-MTP Pre-Term LSZH APAC
LANmark-OF ENSPACE Method B MTP-MTP Pre-Term LSZH APAC
- Factory terminated MTP-MTP fibre assembly
- Flexible fan-out for ease of installation in patch panel
- Small cable diameter reduces required data centre space
- Method B polarity Pre-Term
- Optimized for 40G/100G parallel transmission
- Fibre count: 12F, 24F, 48F, 96F
- Fibre type: OM3, OM4,OM5 and Singlemode (OS2 G.657.A1)
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM3 Aqua
Nexans ref. N145.B12MMExxxA
- 包装: Unit
- 光纤类型: OM3 50/125
- 光纤数: 12
- 标称外径: 3.65 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 450 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM4 Aqua
Nexans ref. N147.B12MMExxxA
- 包装: Unit
- 光纤类型: OM4 50/125
- 光纤数: 12
- 标称外径: 3.65 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 450 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM5 Lime Green
Nexans ref. N149.B12MMExxxL
- 包装: Unit
- 光纤类型: OM5 50/125
- 光纤数: 12
- 标称外径: 3.65 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 450 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM3 Aqua
Nexans ref. N145.B24MMExxxA
- 包装: Unit
- 光纤类型: OM3 50/125
- 光纤数: 24
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM4 Aqua
Nexans ref. N147.B24MMExxxA
- 包装: Unit
- 光纤类型: OM4 50/125
- 光纤数: 24
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM5 Lime Green
Nexans ref. N149.B24MMExxxL
- 包装: Unit
- 光纤类型: OM5 50/125
- 光纤数: 24
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM3 Aqua
Nexans ref. N145.B48MMExxxA
- 包装: Unit
- 光纤类型: OM3 50/125
- 光纤数: 48
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM4 Aqua
Nexans ref. N147.B48MMExxxA
- 包装: Unit
- 光纤类型: OM4 50/125
- 光纤数: 48
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM5 Lime Green
Nexans ref. N149.B48MMExxxL
- 包装: Unit
- 光纤类型: OM5 50/125
- 光纤数: 48
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM3 Aqua
Nexans ref. N145.B96MMExxxA
- 包装: Unit
- 光纤类型: OM3 50/125
- 光纤数: 96
- 标称外径: 6.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 1000 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM4 Aqua
Nexans ref. N147.B96MMExxxA
- 包装: Unit
- 光纤类型: OM4 50/125
- 光纤数: 96
- 标称外径: 6.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 1000 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM5 Lime Green
Nexans ref. N149.B96MMExxxL
- 包装: Unit
- 光纤类型: OM5 50/125
- 光纤数: 96
- 标称外径: 6.4 mm
- 最小回波损耗,dB: 20 dB
- 最大安装拉力: 1000 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 12c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Nexans ref. N144.B12MMExxxY
- 包装: Unit
- 光纤类型: SM (G657.A1)
- 光纤数: 12
- 标称外径: 3.65 mm
- 最小回波损耗,dB: 45 dB
- 最大安装拉力: 450 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 24c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Nexans ref. N144.B24MMExxxY
- 包装: Unit
- 光纤类型: SM (G657.A1)
- 光纤数: 24
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 45 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 48c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Nexans ref. N144.B48MMExxxY
- 包装: Unit
- 光纤类型: SM (G657.A1)
- 光纤数: 48
- 标称外径: 5.4 mm
- 最小回波损耗,dB: 45 dB
- 最大安装拉力: 660 N
LANmark-OF ENSPACE METHOD B MTP/M-MTP/M Pre-Term SM 96c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Nexans ref. N144.B96MMExxxY
- 包装: Unit
- 光纤类型: SM (G657.A1)
- 光纤数: 96
- 标称外径: 6.4 mm
- 最小回波损耗,dB: 45 dB
- 最大安装拉力: 1000 N
Description
Description
Standards
-
ProductANSI/TIA-568-C.3
-
国际ISO/IEC 11801
Pre-Term for data centres, buildings and campus based on Micro-Bundle Universal
The cable has a small diameter and bend raduis to meet data centre requirements.
Fire performance
The cables have been tested for fire performance according to IEC 60332-3c. The cable meets LSZH requirements.
MTP*-MTP Pre-Term characteristics
The MTP-MTP Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the ENSPACE modules and the female Plug&Play modules.
In order to reduce overlengths in data centers the Pre-Terms are custom made and available with 1m increments. The "xxx" in the N-number is the length in metre between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.
The Pre-Terms are optimized for both pulling and laying in data centers. On both sides the MTP connectors are protected by a bubble foam. The maximum pulling force on the pulling eye is 450N. The detachable pulling eye with corrugrated tube can be ordered using PN N890.100HP.
The MTP-MTP Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF ENSPACE and Plug&Play patch panel slots.
Optical Performance and Polarity
The insertion loss for a multimode the MTP-MTP* connection has Low Loss performance: typical insertion loss is 0,15 dB with a maximum of 0,35 dB insertion loss. Ultra Low loss is also available with typical insertion loss 0.125dB with a maximum of 0.25dB insertion loss.
The insertion loss for a singlemode the MTP-MTP* connection has Low Loss performance: typical insertion loss 0.3dB with a maximum of 0.35dB insertion loss.
The insertion loss of a MTP-MTP* connection is measured according to standard IEC61300-3-45.
The minimum return loss for a multimode MTP connection is 20 dB measured according to IEC 61300-3-6. The minimum return loss for a singlemode MTP connection is 45 dB measured according to IEC 61300-3-6.
The method B Pre-Term has a key up / key up design. This is in agreement with standard TIA-568.3-D-2016 method B.
Characteristics
Characteristics
结构特性
结构特性
传输特性
传输特性
机械特性
机械特性
使用特性
使用特性
Resources
Resources
我们的网站
选择你的国家查找我们的产品和解决方案
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania