FLOWGUARD LSZH 24XSM G652D SP1905 BK

Aginode ref. 10563593

  • Colour: Black
  • Number of tubes: 2
  • Number of optical fibres: 24

 

FLOWGUARD LSZH 48XSM G652D SP1905 BK

Aginode ref. 10565775

  • Colour: Black
  • Number of tubes: 4
  • Number of optical fibres: 48

 

Description

Description

Standards

EN 50200; EN 50399; IEC 60332-1; IEC 60332-3; IEC 60754-2; IEC 60794; IEC 61034

Multi micro-modules cable with dielectric FRP armour:

 

This FLOWGUARD™ (ref. SP1905) is designed for indoor/outdoor installation in railways/tunnel infrastructure.

The FRP armour provides a high rodent protection. This cable has an  outstanding fire behaviour.

This cable can be operated under a wide temperature range.

FLOWGUARD™ is fire resistant (circuit integrity) following EN50200 during 120minutes.

 

Waterproof dry core structure.

 

Design

The FLOWGUARD™ LSZH*  cable has a central strength member (FRP : Fibre Reinforced Plastic), with bundles (maximum 12 fibres per bundle) around. The design is reinforced by a first layer of aramid yarns, a LSZH* inner sheath, a FRP composed armour and a LSZH* outer steath.

A ripcord is placed beneath the inner and outer sheath for an easy access to the micro-modules.

 

Fibre type

The FLOWGUARD™ LSZH* cable is available with singlemode and multimode fibres.

 

Technical performances

The cable performances are specified in the following tables.

 

Additional details

This cable is provided as a standard with a black sheath, other sheath colours are also available. Long exposure to UV with these other colours could generate colour fading.

 

Euroclass

B2ca S1a a1 d0

 

* LSZH: Low Smoke Zero Halogen.

Characteristics

Characteristics

Construction characteristics
Colour
Black
Armour type
FRP
Halogen free
IEC 60754-1
Metal free
Yes
Strength member
Central FRP
Additional strength member
Aramide
Dimensional characteristics
Number of tubes
2
Approximate weight
172 kg/km
Number of optical fibres
24
Nominal outer diameter
12.4 mm
Mechanical characteristics
Mechanical resistance to impacts
10 impacts of 3 N.m
Maximum permanent tensile load
2 kN
Crush resistance (IEC 60794-1-E3)
300 N/cm
Maximum installation tension
6000 N
Usage characteristics
Rodent protection
FRP
Operating temperature, range
-30...60 °C
Fire resistant
UNE-EN50200 PH120
Fire retardant
IEC 60332-3
Flame retardant
IEC 60332-1
Smoke density
IEC 61034-2
Storage temperature, range
-30...60 °C
Installation type
Indoor/Outdoor
Installation temperature, range
-5...40 °C

Resources

Resources

Selling & delivery Information

Standard Marking

Aginode FLOWGUARD FIBRE OPTIC CABLE LSZH - SP1905 - XXxYY - FB - TN - metric

XX = Fibre Count YY = Fibre Type FB = Frameries, Belgium (manufacturing place) TN = Traceability Number