LANmark-OF MPO-MPO Pre-Term OFNP Method C APAC
LANmark-OF MPO-MPO Pre-Term OFNP Method C APAC
- Factory terminated MPO-MPO fibre assembly
- Flexible fan-out for ease of installation in patch panel
- Small cable diameter reduces required data centre space
- Method C polarity Pre-Term
- Only one type of patch cords and one type of cassettes required for duplex transmission
- Fibre count: 12F, 24F, 48F, 96F
- Fibre type: OM3, OM4 and singlemode (OS2 G.657.A1)
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 24c OFNP xxxM Yellow
Aginode ref. N144.CU24SPxxx-PY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 24
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 48c OFNP xxxM Yellow
Aginode ref. N144.CU48SPxxx-PY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 48
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 96c OFNP xxxM Yellow pulling eye one side
Aginode ref. N144.CU96SAxxx-PY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 96
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM3 12c OFNP xxxM Aqua
Aginode ref. N145.CU12LPxxx-PA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 12
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM3 24c OFNP xxxM Aqua
Aginode ref. N145.CU24LPxxx-PA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 24
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM3 48c OFNP xxxM Aqua
Aginode ref. N145.CU48LPxxx-PA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 48
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM3 96c OFNP xxxM Aqua pulling eye one side
Aginode ref. N145.CU96LAxxx-PA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 96
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 12c OFNP xxxM Aqua
Aginode ref. N147.CU12LPxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 12
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 24c OFNP xxxM Aqua
Aginode ref. N147.CU24LPxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 24
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 48c OFNP xxxM Aqua
Aginode ref. N147.CU48LPxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 48
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 96c OFNP xxxM Aqua pulling eye one side
Aginode ref. N147.CU96LAxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 96
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 12c OFNP xxxM Yellow
Aginode ref. N144.CU12SPxxx-PY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 12
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 12c OFNP Ultra Low loss xxxM Aqua
Aginode ref. N147.CU12UPxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 12
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term MM OM4 24c Ultra Low loss OFNP xxxM Aqua
Aginode ref. N147.CU24UPxxx-PA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 24
Description
Description
Standards
Pre-Term for data centres, buildings and campus based on Micro-Bundle.
The cable has a small diameter and bend raduis to meet data centre requirements.
Fire performance
The cables have been tested for fire performance according to Plenum fire performance, providing a very high fire performance with minimal fire load and can be used in air flow space.
MPO-MPO Pre-Term characteristics
The MPO-MPO Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the female Plug&Play modules.
In order to reduce overlengths in data centers the Pre-Terms are custom made and available with 1m increments. The "xxx" in the N-number is the length in metre between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.
After the cable gland the Pre-Term has a fan-out. The fan-out splits the cable into tubes. The tubes are reinforced with aramid yarns. At the end of each tube a MPO-connectors is mounted. The jacket of the tube is the same colour as the cable jacket. Close to the MPO-connector a label is installed to identify the number of the leg.
The MPO-MPO Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF Plug&Play patch panel slots.
Optical Performance and Polarity
The insertion loss for a multimode the MPO-MPO connection has Ultra Low Loss performance: typical insertion loss is 0,2 dB with a maximum of 0,35 dB insertion loss.
The typical insertion loss for a singlemode the MPO-MPO connection is 0,5 dB with a maximum of 0,75 dB insertion loss.
The insertion loss of a MPO-MPO connection is measured according to standard IEC61300-3-45.
The minimum return loss for a multimode MPO connection is 20 dB . The minimum return loss for a singlemode MPO connection is 45 dB. The measurement is according to IEC 61300-3-6.