LANmark-OF ENSPACE Method C MTP-MTP Pre-Term LSZH APAC
LANmark-OF ENSPACE Method C MTP-MTP Pre-Term LSZH APAC
- Factory terminated MTP-MTP fibre assembly
- Flexible fan-out for ease of installation in patch panel
- Small cable diameter reduces required data centre space
- Method C polarity Pre-Term
- Only one type of patch cords and one type of cassettes required for duplex transmission
- Fibre count: 12F, 24F, 48F, 96F
- Fibre type: OM3, OM4,OM5 and Singlemode (OS2 G.657.A1)
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 12c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.C12MMExxxY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 12
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 24c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.C24MMExxxY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 24
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 48c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.C48MMExxxY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 48
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 96c Low Loss LSZH xxxM OS2 G.657.A1 Yellow
Aginode ref. N144.C96MMExxxY
- Fiber optic type: SM (G657.A1)
- Number of optical fibres: 96
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.C12MMExxxA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 12
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.C24MMExxxA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 24
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.C48MMExxxA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 48
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM3 Aqua
Aginode ref. N145.C96MMExxxA
- Fiber optic type: OM3 50/125
- Number of optical fibres: 96
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.C12MMExxxA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 12
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.C24MMExxxA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 24
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.C48MMExxxA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 48
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM4 Aqua
Aginode ref. N147.C96MMExxxA
- Fiber optic type: OM4 50/125
- Number of optical fibres: 96
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.C12MMExxxL
- Fiber optic type: OM5 50/125 Wideband
- Number of optical fibres: 12
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.C24MMExxxL
- Fiber optic type: OM5 50/125 Wideband
- Number of optical fibres: 24
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.C48MMExxxL
- Fiber optic type: OM5 50/125 Wideband
- Number of optical fibres: 48
LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM5 Lime Green
Aginode ref. N149.C96MMExxxL
- Fiber optic type: OM5 50/125 Wideband
- Number of optical fibres: 96
Description
Description
Standards
Pre-Term for data centres, buildings and campus based on Micro-Bundle Universal
The cable has a small diameter and bend raduis to meet data centre requirements.
Fire performance
The cables have been tested for fire performance according to IEC 60332-3c. The cable meets LSZH requirements.
MTP*-MTP Pre-Term characteristics
The MTP-MTP Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the ENSPACE modules and the female Plug&Play modules.
In order to reduce overlengths in data centers the Pre-Terms are custom made and available with 1m increments. The "xxx" in the N-number is the length in metre between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.
The Pre-Terms are optimized for both pulling and laying in data centers. On both sides the MTP connectors are protected by a bubble foam. The maximum pulling force on the pulling eye is 450N. The detachable pulling eye with corrugrated tube can be ordered using PN N890.100HP.
The MTP-MTP Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF ENSPACE and Plug&Play patch panel slots.
Optical Performance and Polarity
The insertion loss for a multimode the MTP-MTP* connection has Low Loss performance: typical insertion loss is 0,15 dB with a maximum of 0,35 dB insertion loss. Ultra Low loss is also available with typical insertion loss 0.125dB with a maximum of 0.25dB insertion loss.
The insertion loss for a singlemode the MTP-MTP* connection has Low Loss performance: typical insertion loss 0.3dB with a maximum of 0.35dB insertion loss.
The insertion loss of a MTP-MTP* connection is measured according to standard IEC61300-3-45.
The minimum return loss for a multimode MTP connection is 20 dB measured according to IEC 61300-3-6. The minimum return loss for a singlemode MTP connection is 45 dB measured according to IEC 61300-3-6.
The method C Pre-Term has a pairflip key up / key down design. This is in agreement with standard TIA-568.3-D-2016 method C.