LANmark-OF ENSPACE Method C MTP-MTP Pre-Term LSZH APAC

Products

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM3 Aqua

Nexans ref. N145.C12MMExxxA

  • 包装: Unit
  • 光纤类型: OM3 50/125
  • 光纤数: 12
  • 标称外径: 3.65 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 450 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM4 Aqua

Nexans ref. N147.C12MMExxxA

  • 包装: Unit
  • 光纤类型: OM4 50/125
  • 光纤数: 12
  • 标称外径: 3.65 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 450 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 12c Low Loss LSZH xxxM OM5 Lime Green

Nexans ref. N149.C12MMExxxL

  • 包装: Unit
  • 光纤类型: OM5 50/125
  • 光纤数: 12
  • 标称外径: 3.65 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 450 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM3 Aqua

Nexans ref. N145.C24MMExxxA

  • 包装: Unit
  • 光纤类型: OM3 50/125
  • 光纤数: 24
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM4 Aqua

Nexans ref. N147.C24MMExxxA

  • 包装: Unit
  • 光纤类型: OM4 50/125
  • 光纤数: 24
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 24c Low Loss LSZH xxxM OM5 Lime Green

Nexans ref. N149.C24MMExxxL

  • 包装: Unit
  • 光纤类型: OM5 50/125
  • 光纤数: 24
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM3 Aqua

Nexans ref. N145.C48MMExxxA

  • 包装: Unit
  • 光纤类型: OM3 50/125
  • 光纤数: 48
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM4 Aqua

Nexans ref. N147.C48MMExxxA

  • 包装: Unit
  • 光纤类型: OM4 50/125
  • 光纤数: 48
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 48c Low Loss LSZH xxxM OM5 Lime Green

Nexans ref. N149.C48MMExxxL

  • 包装: Unit
  • 光纤类型: OM5 50/125
  • 光纤数: 48
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM3 Aqua

Nexans ref. N145.C96MMExxxA

  • 包装: Unit
  • 光纤类型: OM3 50/125
  • 光纤数: 96
  • 标称外径: 6.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 1000 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM4 Aqua

Nexans ref. N147.C96MMExxxA

  • 包装: Unit
  • 光纤类型: OM4 50/125
  • 光纤数: 96
  • 标称外径: 6.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 1000 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term MM 96c Low Loss LSZH xxxM OM5 Lime Green

Nexans ref. N149.C96MMExxxL

  • 包装: Unit
  • 光纤类型: OM5 50/125
  • 光纤数: 96
  • 标称外径: 6.4 mm
  • 最小回波损耗,dB: 20 dB
  • 最大安装拉力: 1000 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 12c Low Loss LSZH xxxM OS2 G.657.A1 Yellow

Nexans ref. N144.C12MMExxxY

  • 包装: Unit
  • 光纤类型: SM (G657.A1)
  • 光纤数: 12
  • 标称外径: 3.65 mm
  • 最小回波损耗,dB: 45 dB
  • 最大安装拉力: 450 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 24c Low Loss LSZH xxxM OS2 G.657.A1 Yellow

Nexans ref. N144.C24MMExxxY

  • 包装: Unit
  • 光纤类型: SM (G657.A1)
  • 光纤数: 24
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 45 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 48c Low Loss LSZH xxxM OS2 G.657.A1 Yellow

Nexans ref. N144.C48MMExxxY

  • 包装: Unit
  • 光纤类型: SM (G657.A1)
  • 光纤数: 48
  • 标称外径: 5.4 mm
  • 最小回波损耗,dB: 45 dB
  • 最大安装拉力: 660 N

 

LANmark-OF ENSPACE Method C MTP/M-MTP/M Pre-Term SM 96c Low Loss LSZH xxxM OS2 G.657.A1 Yellow

Nexans ref. N144.C96MMExxxY

  • 包装: Unit
  • 光纤类型: SM (G657.A1)
  • 光纤数: 96
  • 标称外径: 6.4 mm
  • 最小回波损耗,dB: 45 dB
  • 最大安装拉力: 1000 N

 

Description

Description

Standards

  • International
    ISO/IEC 11801
  • National
    ANSI/TIA-568-C.3

Pre-Term for data centres, buildings and campus based on Micro-Bundle Universal

The cable has a small diameter and bend raduis to meet data centre requirements.

Fire performance

The cables have been tested for fire performance according to IEC 60332-3c. The cable meets LSZH requirements.

MTP*-MTP Pre-Term characteristics

The MTP-MTP Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the ENSPACE modules and the female Plug&Play modules.

In order to reduce overlengths in data centers the Pre-Terms are custom made and available with 1m increments. The "xxx" in the N-number is the length in metre between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.

The Pre-Terms are optimized for both pulling and laying in data centers. On both sides the MTP connectors are protected by a bubble foam. The maximum pulling force on the pulling eye is 450N. The detachable pulling eye with corrugrated tube can be ordered using PN N890.100HP.

The MTP-MTP Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF ENSPACE and Plug&Play patch panel slots.

Optical Performance and Polarity

The insertion loss for a multimode the MTP-MTP* connection has Low Loss performance: typical insertion loss is 0,15 dB with a maximum of 0,35 dB insertion loss. Ultra Low loss is also available with typical insertion loss 0.125dB with a maximum of 0.25dB insertion loss.

The insertion loss for a singlemode the MTP-MTP* connection has Low Loss performance:  typical insertion loss 0.3dB with a maximum of 0.35dB insertion loss.

The insertion loss of a MTP-MTP* connection is measured according to standard IEC61300-3-45.

The minimum return loss for a multimode MTP connection is 20 dB measured according to IEC 61300-3-6. The minimum return loss for a singlemode MTP connection is 45 dB measured according to IEC 61300-3-6.

The method C Pre-Term has a pairflip key up / key down design. This is in agreement with standard TIA-568.3-D-2016 method C.

Characteristics

Characteristics

结构特性

结构特性

无卤

传输特性

传输特性

最大插入损耗,dB
0.35 dB

机械特性

机械特性

机械耐冲击性能
10次冲击/ 3N.M
耐挤压 (IEC 794-1-E3)
100 N/cm

使用特性

使用特性

操作温度范围
-20 ... 60 °C
最小弯曲半径 - 静态(XD)
10
最小弯曲半径 - 动态
20 (xD)
烟密度
IEC 61034
阻燃
IEC 60332-3-24 (cat C)

Resources

Resources

联系我们

您需要获得更多信息的话题

必填字段*

请检查您的输入重新尝试

所有的邮箱地址必须包含一个单独的@

个人数据保护

您有权反对将您的个人数据和/或将其用于直接营销或商业目的

谢谢

感谢垂询。我们将尽快和您联系。

错误

发生错误。请重试。

关闭