Skip to main content

Aerial - ADSS Microbundle Cables

Products

Microbundle RSM cable 8x6SM SP1939

Aginode ref.

  • Approximate weight: 66 (kg/km)
  • Nominal outer diameter: 9.5 (mm)
  • Number of optical fibres: 48
  • Number of tubes: 8
  • Maximum admissible traction load (Tm): 140 (daN)
  • Maximum tensile load during service (Tl): 47.0 (daN)

 

Microbundle RSM cable 12x6SM SP1931

Aginode ref.

  • Approximate weight: 99 (kg/km)
  • Nominal outer diameter: 11.4 (mm)
  • Number of optical fibres: 72
  • Number of tubes: 12
  • Maximum admissible traction load (Tm): 210 (daN)
  • Maximum tensile load during service (Tl): 70.0 (daN)

 

Microbundle RSM cable 6x6SM SP1932

Aginode ref.

  • Approximate weight: 63 (kg/km)
  • Nominal outer diameter: 9.3 (mm)
  • Number of optical fibres: 36
  • Number of tubes: 6
  • Maximum admissible traction load (Tm): 133 (daN)
  • Maximum tensile load during service (Tl): 44.0 (daN)

 

Microbundle_RSM cable 4x6SM SP1932

Aginode ref.

  • Approximate weight: 62.5 (kg/km)
  • Nominal outer diameter: 9.2 (mm)
  • Number of optical fibres: 24
  • Number of tubes: 4
  • Maximum admissible traction load (Tm): 131 (daN)
  • Maximum tensile load during service (Tl): 44.0 (daN)

 

Microbundle RSM cable 8x6SM SP1939 ETC

Aginode ref. 10563027

  • Approximate weight: 71 (kg/km)
  • Nominal outer diameter: 9.5 (mm)
  • Number of optical fibres: 48
  • Number of tubes: 8
  • Maximum admissible traction load (Tm): 220 (daN)
  • Maximum tensile load during service (Tl): 73.3 (daN)

 

Microbundle RSM cable 16x6SM SP1936

Aginode ref.

  • Approximate weight: 123 (kg/km)
  • Nominal outer diameter: 12.7 (mm)
  • Number of optical fibres: 96
  • Number of tubes: 16
  • Maximum admissible traction load (Tm): 280 (daN)
  • Maximum tensile load during service (Tl): 93.0 (daN)

 

Microbundle_RSM cable 2x6SM SP1941

Aginode ref.

  • Approximate weight: 48.7 (kg/km)
  • Nominal outer diameter: 8.6 (mm)
  • Number of optical fibres: 12
  • Number of tubes: 2
  • Maximum admissible traction load (Tm): 120 (daN)
  • Maximum tensile load during service (Tl): 40.0 (daN)

 

Microbundle_RSM cable 2x12SM SP1949

Aginode ref.

  • Approximate weight: 48 (kg/km)
  • Nominal outer diameter: 8.1 (mm)
  • Number of optical fibres: 24
  • Number of tubes: 2
  • Maximum admissible traction load (Tm): 98 (daN)
  • Maximum tensile load during service (Tl): 33.0 (daN)

 

Microbundle_RSM cable 4x12SM SP1947

Aginode ref.

  • Approximate weight: 57 (kg/km)
  • Nominal outer diameter: 9.1 (mm)
  • Number of optical fibres: 48
  • Number of tubes: 4
  • Maximum admissible traction load (Tm): 130 (daN)
  • Maximum tensile load during service (Tl): 43.0 (daN)

 

Microbundle_RSM cable 3x12SM SP1947

Aginode ref.

  • Approximate weight: 57 (kg/km)
  • Nominal outer diameter: 9.1 (mm)
  • Number of optical fibres: 36
  • Number of tubes: 3
  • Maximum admissible traction load (Tm): 130 (daN)
  • Maximum tensile load during service (Tl): 43.0 (daN)

 

Microbundle RSM cable 6x12SM SP1948

Aginode ref.

  • Approximate weight: 64 (kg/km)
  • Nominal outer diameter: 9.5 (mm)
  • Number of optical fibres: 72
  • Number of tubes: 6
  • Maximum admissible traction load (Tm): 141 (daN)
  • Maximum tensile load during service (Tl): 47.0 (daN)

 

Microbundle RSM cable 8x12SM SP1946

Aginode ref.

  • Approximate weight: 90 (kg/km)
  • Nominal outer diameter: 10.7 (mm)
  • Number of optical fibres: 96
  • Number of tubes: 8
  • Maximum admissible traction load (Tm): 181 (daN)
  • Maximum tensile load during service (Tl): 60.0 (daN)

 

Microbundle RSM cable 12x12SM SP1945

Aginode ref.

  • Approximate weight: 115 (kg/km)
  • Nominal outer diameter: 12.2 (mm)
  • Number of optical fibres: 144
  • Number of tubes: 12
  • Maximum admissible traction load (Tm): 245 (daN)
  • Maximum tensile load during service (Tl): 82.0 (daN)

 

Microbundle_RSM cable 1x12SM SP1949

Aginode ref.

  • Approximate weight: 40 (kg/km)
  • Nominal outer diameter: 8.1 (mm)
  • Number of optical fibres: 12
  • Number of tubes: 1
  • Maximum admissible traction load (Tm): 98 (daN)
  • Maximum tensile load during service (Tl): 33.0 (daN)

 

Description

Description

Standards

EN 187000; IEC 60794

This ruggedized cable is used for Access, Distribution, City Network and FTTx applications.It is designed to be quickly installed aerial or in duct.

 

Characteristics & Applications

  • Compliant with XPC 93850-3-25 
  • Ruggedized cable design
  • Easy installation with mid span access possibility
  • Easy micro bundle stripability
  • All dielectric design
  • Waterproof structure

 

Construction

  • Jelly filled microbundles containing  coloured fibres
  • FRP strength member reinforcements
  • Aramid yarns reinforcement
  • HDPE outer sheath
     

Characteristics

Characteristics

Construction characteristics
Fiber optic type
SM (G657.A1)
Armour type
Aramid yarn
Outer sheath
HDPE
Metal free
Yes
Strength member
FRP
Construction type
Multibundle
Mechanical characteristics
Crush resistance (IEC 60794-1-E3)
300 N/cm
Usage characteristics
Operating temperature, range
-40...70 °C
Storage temperature, range
-40...70 °C
Ambient installation temperature, range
-15...40 °C
Bending factor when laying
20 (xD)

Resources

Resources

Selling & delivery Information

Standard Marking

Aginode - SPxxxx - FIBRE OPTIC CABLE - XX*YY - FB - TN - metric


XX = Fibre Count
YY = Fibre Type 
FB = Produced in Frameries, Belgium
TN = Traceability Number