- À propos d'Aginode
- Data Network Solutions
- Réseaux télécom - Infrastructures
- Produits
-
Ressources
- Ressources
- Documentation
- Blog
-
Success-stories
- Présentation
- Développement d'Innoasis en Norvège
- Campus Eemsdelta
- École hôtelière de La Haye
- Emergency covid hospital, Hong Kong
- Société du Grand Paris
- Centrin Datacentres
- Airbus
- Hôtel de ville historique d'Athènes
- Câblage des Studios Pinewood pour la haute définition
- L'Université Johan Wolfgang Goethe de Francfort
- Nouvel Hôpital Universitaire au Danemark
- Université de Toulouse
- Le Nouveau Centre Hospitalier de Maubeuge (CHM) : un modèle pour les hôpitaux du futur
- Webinaires
- Outils logiciels
- Garantie
- Actualités et événements
- Recherche
- Contactez-nous
- Comparer
- Se connecter
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 96c OFNP xxxM Yellow pulling eye one side
LANmark-OF METHOD C MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 96c OFNP xxxM Yellow pulling eye one side
- Factory terminated MPO-MPO fibre assembly
- Flexible fan-out for ease of installation in patch panel
- Small cable diameter reduces required data centre space
- Method C polarity Pre-Term
- Only one type of patch cords and one type of cassettes required for duplex transmission
- Fibre count: 96F
- Fibre type: SingleMode OS2 G.657.A1
- Réf. Nexans : N144.CU96SAxxx-PY
Description
Description
Normes
-
InternationalISO/IEC 11801
Pre-Term for data centres, buildings and campus based on Micro-Bundle.
The cable has a small diameter and bend raduis to meet data centre requirements.
Fire performance
The cables have been tested for fire performance according to Plenum rated, providing a very high fire performance with minimal fire load and can be used in air flow space.
MPO-MPO Pre-Term characteristics
The MPO-MPO Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the female Plug&Play modules.
The "xxx" in the N-number is the length in meter between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.
After the cable gland the Pre-Term has a fan-out. The fan-out splits the cable into tubes. The tubes are reinforced with aramid yarns.
Pre-terminated MPO fibre cable can be ordered separately with a removable pulling eye for fast deployment onsite. The pulling eye provides minimum 450N installation tension. The removable pulling eye can be quickly detached after installation and can be reinstalled, reducing construction waste and making it more suitable for sustainable environmental protection. The detachable pulling eye with corrugrated tube can be ordered using PN N890.100HP.
Prefabricated pulling eye is also available with the MPO pre-term.
The MPO-MPO Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF Plug&Play patch panel slots.
Optical Performance and Polarity
The typical insertion loss for a singlemode the MPO-MPO connection is 0,5 dB with a maximum of 0,75 dB insertion loss. The insertion loss of a MPO-MPO connection is measured according to standard IEC61300-3-45.
The minimum return loss for a singlemode MPO connection is 45 dB measured according to IEC 61300-3-6.
The method C Pre-Term has a pair flip key up / key down design. This is in agreement with standard TIA-568.3-D-2016 method C.
Caractéristiques
Caractéristiques
Caractéristiques de construction
Caractéristiques de construction
Caractéristiques dimensionnelles
Caractéristiques dimensionnelles
Caractéristiques de transmission
Caractéristiques de transmission
Caractéristiques mécaniques
Caractéristiques mécaniques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Ressources
Ressources
Nos sites web
Sélectionnez votre pays pour trouver nos produits et solutions
-
Afrique
- Afrique
- Côte d'Ivoire
- Ghana
- Maroc
- Zone Afrique du Nord
- Amériques
- Asie
- Europe
- Océanie