- À propos d'Aginode
- Data Network Solutions
- Réseaux télécom - Infrastructures
- Produits
-
Ressources
- Ressources
- Documentation
- Blog
-
Success-stories
- Présentation
- Développement d'Innoasis en Norvège
- Campus Eemsdelta
- École hôtelière de La Haye
- Emergency covid hospital, Hong Kong
- Société du Grand Paris
- Centrin Datacentres
- Airbus
- Hôtel de ville historique d'Athènes
- Câblage des Studios Pinewood pour la haute définition
- L'Université Johan Wolfgang Goethe de Francfort
- Nouvel Hôpital Universitaire au Danemark
- Université de Toulouse
- Le Nouveau Centre Hospitalier de Maubeuge (CHM) : un modèle pour les hôpitaux du futur
- Webinaires
- Outils logiciels
- Garantie
- Actualités et événements
- Recherche
- Contactez-nous
- Comparer
- Se connecter
LANmark-OF METHOD B MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 12c LSZH xxxM Yellow Pulling Eye one side
LANmark-OF METHOD B MPO/M-MPO/M Pre-Term SM OS2 G.657.A1 12c LSZH xxxM Yellow Pulling Eye one side
- Factory terminated MPO-MPO fibre assembly
- Flexible fan-out for ease of installation in patch panel
- Small cable diameter reduces required data centre space
- Method B polarity Pre-Term
- Optimized for 40G/100G parallel transmission
- Fibre count: 12F
- Fibre type: Singlemode OS2 G.657.A1
- Réf. Nexans : N144.BL12SAxxx-LY
Description
Description
Normes
-
ProduitANSI/TIA-568-C.3
-
InternationalISO/IEC 11801
Pre-Term for data centres, buildings and campus based on Micro-Bundle Universal
The cable has a small diameter and bend raduis to meet data centre requirements.
Fire performance
The cables have been tested for fire performance according to IEC 60332-3c. The cable meets LSZH requirements.
MPO-MPO Pre-Term characteristics
The Pre-Term has standard pinned (male) MPO connectors. This matches with the un-pinned (female) connectors in the female Plug&Play MPO-LC modules.
In order to reduce overlengths in data centers the Pre-Terms are custom made and available with 1m increments. The "xxx" in the N-number is the length in metre between the cable glands, i.e. the Pre-Term length between the back side of the patch panels.
The Pre-Terms are optimized for both pulling and laying in data centers. On both sides the MPO connectors are protected by a bubble foam. The maximum pulling force on the pulling eye is 450N. Pre-term are ordered with 2 options available: Pulling eye on one side or No pulling eye. A detachable pulling eye with corrugrated tube can be ordered separately using PN N890.100HP.
The MPO Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF Plug&Play patch panel gland holders.
Optical Performance and Polarity
The insertion loss for a multimode the MPO connection has typical Low Loss performance of 0,2 dB and with a maximum of 0,35 dB insertion loss.
The insertion loss for a singlemode the MPO connection has typical performance of 0.5dB with a maximum of 0.75dB insertion loss.
The insertion loss of a MPO connection is measured according to standard IEC61300-3-45.
The minimum return loss for a multimode MPO connection is 20 dB and singlemode MPO connection is 45 dB, both measured according to IEC 61300-3-6.
The method B Pre-Term has a key up / key up design. This is in agreement with standard TIA-568.3-D-2016 method B.
Caractéristiques
Caractéristiques
Caractéristiques de construction
Caractéristiques de construction
Caractéristiques dimensionnelles
Caractéristiques dimensionnelles
Caractéristiques de transmission
Caractéristiques de transmission
Caractéristiques mécaniques
Caractéristiques mécaniques
Caractéristiques d'utilisation
Caractéristiques d'utilisation
Ressources
Ressources
Nos sites web
Sélectionnez votre pays pour trouver nos produits et solutions
-
Afrique
- Afrique
- Côte d'Ivoire
- Ghana
- Maroc
- Zone Afrique du Nord
- Amériques
- Asie
- Europe
- Océanie