LANmark-OF Drop Cable Up to 12FO - B2ca

Description

Description

Standards

  • International
    ISO/IEC 11801

Description and Application

This reinforced drop cable is ideally used for indoor/outdoor deployments integrating the new generation of bend insensitive fibres. This compact cable allows low bending radius and can be installed in indoor and outdoor environment. This cable is totally adapted to fire performance conditions with the highest level in the European regulation: B2ca CPR level. Its outersheath is in LSZH material (Low Smoke, Zero Halogen) which reduces the smoke creation and does not generate toxic hologen fumes when burning. This cable operates over a large temperature range.

 

Construction

Legend accompanying the cross section drawing:

  1. Optical fiber 250µm
  2. Micro Bundle
  3. Reinforcing watertight glass yarns
  4. LSZH jacket
  5. Aramid yarns

 

Characteristics

  • Reaction to fire B2ca-s1,d0,a1 according to EN50575:2014+A1:2016
  • Easy strippable Micro Bundle containing up to 12 fibres
  • Low Bending radius
  • All dielectric design
  • Watertight structure
  • Flame non propagation (IEC 60332-1)
  • Fire non propagation (IEC 60332-3)

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Construction type
Unibundle
Material used for longitudinal water tightness
Watertight glass yarns
Additional strength member
Glass yarn
Outer sheath
LSZH
Halogen free
IEC 60754-1
Metal free
Yes
Fiber optic type
-

Dimensional characteristics

Dimensional characteristics

Number of optical fibres
-
Approximate weight
21 kg/km
Nominal outer diameter
- mm

Mechanical characteristics

Mechanical characteristics

Maximum installation tension
750 N
Maximum permanent tensile load
0.2 kN
Crush resistance (IEC 60794-1-E3)
- N/cm
Mechanical resistance to impacts
10 impacts of 3 N.m

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3
Smoke density
IEC 61034-2
U.V resistance
Very good
Water proof
Longitudinal & radial
Installation type
Indoor/Outdoor
Installation temperature, range
0 ... 40 °C
Storage temperature, range
- °C
操作温度范围
- °C
Minimum static operating bending radius
15 mm
Laying operation bending radius
15 mm

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close