LANmark-OF ENSPACE Method B MTP-MTP Pre-Term OFNP APAC

Products

LANmark-OF ENSPACE Method B 12F x OM3 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N145.O12MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 12
  • Nominal outer diameter: 4.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 450 N

 

LANmark-OF ENSPACE Method B 12F x OM4 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N147.O12MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 12
  • Nominal outer diameter: 4.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 450 N

 

LANmark-OF ENSPACE Method B 12F x SM Ultra Low Loss MTP Male APC - MTP Male APC Pre-Term xxxm OFNP Yellow

Nexans ref. N144.O12MMExxxY

  • Packaging: Cut to length (m)
  • Fiber optic type: SM (G657.A1)
  • Number of optical fibres: 12
  • Nominal outer diameter: 4.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 45 dB
  • Maximum installation tension: 450 N

 

LANmark-OF ENSPACE Method B 24F x OM3 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N145.O24MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 24
  • Nominal outer diameter: 7.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 24F x OM4 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N147.O24MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 24
  • Nominal outer diameter: 7.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 24F x SM Ultra Low Loss MTP Male APC - MTP Male APC Pre-Term xxxm OFNP Yellow

Nexans ref. N144.O24MMExxxY

  • Packaging: Cut to length (m)
  • Fiber optic type: SM (G657.A1)
  • Number of optical fibres: 24
  • Nominal outer diameter: 7.5 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 45 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 48F x OM3 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N145.O48MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 48
  • Nominal outer diameter: 7.7 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 48F x OM4 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N147.O48MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 48
  • Nominal outer diameter: 7.7 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 48F x SM Ultra Low Loss MTP Male APC - MTP Male APC Pre-Term xxxm OFNP Yellow

Nexans ref. N144.O48MMExxxY

  • Packaging: Cut to length (m)
  • Fiber optic type: SM (G657.A1)
  • Number of optical fibres: 48
  • Nominal outer diameter: 7.7 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 45 dB
  • Maximum installation tension: 660 N

 

LANmark-OF ENSPACE Method B 96F x OM3 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N145.O96MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 96
  • Nominal outer diameter: 10.0 mm
  • Insertion Loss, maximum, dB: 0.25 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 1000 N

 

LANmark-OF ENSPACE Method B 96F x OM4 MTP Male - MTP Male Pre-Term xxxm OFNP Aqua

Nexans ref. N147.O96MMExxxA

  • Packaging: Cut to length (m)
  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 96
  • Nominal outer diameter: 10.0 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 20 dB
  • Maximum installation tension: 1000 N

 

LANmark-OF ENSPACE Method B 96F x SM Ultra Low Loss MTP Male APC - MTP Male APC Pre-Term xxxm OFNP Yellow

Nexans ref. N144.O96MMExxxY

  • Packaging: Cut to length (m)
  • Fiber optic type: SM (G657.A1)
  • Number of optical fibres: 96
  • Nominal outer diameter: 10.0 mm
  • Insertion Loss, maximum, dB: 0.35 dB
  • Return Loss, Minimum, dB: 45 dB
  • Maximum installation tension: 1000 N

 

Description

Description

Standards

  • International
    ISO/IEC 11801

Fire performance

The cables have been tested for fire performance according to UL Plenum performance.

According to this standard the cables have a very high fire performance with minimal fire load and can be used in air flow space.

MTP*-MTP Pre-Term characteristics

The MTP-MTP Pre-Term has standard pinned (male) connectors. This matches with the un-pinned (female) connectors in the ENSPACE modules and the female Plug&Play modules.

After the cable gland the Pre-Term has a fan-out. The fan-out splits the cable into tubes. The tubes are reinforced with aramid yarns. At the end of each tube a MTP-connectors is mounted. The jacket of the tube is the same colour as the cable jacket. Close to the MTP-connector a label is installed to identify the number of the leg.

The Pre-Terms are optimized for both pulling and laying in data centers. On both sides the MTP connectors are protected by a bubble foam. The maximum pulling force on the pulling eye is 450N. The detachable pulling eye with corrugrated tube can be ordered using PN N890.100HP.

The MTP-MTP Pre-Terms come with a PG-13 cable gland that fits into the LANmark-OF ENSPACE and Plug&Play patch panel slots.

Optical Performance and Polarity

The insertion loss for a multimode the MTP-MTP* connection has Low Loss performance: typical insertion loss is 0,25 dB with a maximum of 0,35 dB insertion loss. 

The insertion loss for a singlemode the MTP-MTP* connection has Ultra Low Loss performance: typical insertion loss 0.25dB with a maximum of 0.35dB insertion loss.

The insertion loss of a MTP-MTP* connection is measured according to standard IEC61300-3-45.

The minimum return loss for a multimode MTP connection is 20 dB measured according to IEC 61300-3-6. The minimum return loss for a singlemode MTP connection is 45 dB measured according to IEC 61300-3-6.

The method B Pre-Term has a key up / key up design. This is in agreement with standard TIA-568.3-D-2016 method B.

Characteristics

Characteristics

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
10 impacts of 3 N.m
Crush resistance (IEC 60794-1-E3)
100 N/cm

Usage characteristics

Usage characteristics

操作温度范围
-20 ... 60 °C
Minimum bending radius, static (XD)
10
Minimum dynamic operating bending radius
20 (xD)

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close