LANmark-OF UC Outdoor LSZH 48-96core APAC Region

Products

LANmark-OF UC LSZH 48core OM3 Black

Nexans ref. N175.493

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 48
  • Outer Diameter: 10.8 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 1500 N
  • Crush resistance (IEC 60794-1-E3): 1000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 1 N.m
  • Minimum dynamic operating bending radius: 216.0 mm
  • Minimum static operating bending radius: 108 mm

 

LANmark-OF UC LSZH 48core OM4 Black

Nexans ref. N177.493

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 48
  • Outer Diameter: 10.6 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 1500 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 216.0 mm
  • Minimum static operating bending radius: 108 mm

 

LANmark-OF UC LSZH 48core SM G.652.D Black

Nexans ref. N174.493

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 48
  • Outer Diameter: 10.6 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 1500 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 216.0 mm
  • Minimum static operating bending radius: 108 mm

 

LANmark-OF UC LSZH 72core OM3 Black

Nexans ref. N175.505

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 72
  • Outer Diameter: 10.8 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 1500 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 232.0 mm
  • Minimum static operating bending radius: 116 mm

 

LANmark-OF UC LSZH 72core OM4 Black

Nexans ref. N177.505

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 72
  • Outer Diameter: 10.8 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 3000 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 232.0 mm
  • Minimum static operating bending radius: 116 mm

 

LANmark-OF UC LSZH 72core SM G.652.D Black

Nexans ref. N174.505

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 72
  • Outer Diameter: 10.8 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 3000 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 232.0 mm
  • Minimum static operating bending radius: 116 mm

 

LANmark-OF UC LSZH 96core OM3 Black

Nexans ref. N175.517

  • Fiber optic type: OM3 50/125
  • Number of optical fibres: 96
  • Outer Diameter: 13.2 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 3000 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 264.0 mm
  • Minimum static operating bending radius: 132 mm

 

LANmark-OF UC LSZH 96core OM4 Black

Nexans ref. N177.517

  • Fiber optic type: OM4 50/125
  • Number of optical fibres: 96
  • Outer Diameter: 13.2 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 3000 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 264.0 mm
  • Minimum static operating bending radius: 132 mm

 

LANmark-OF UC LSZH 96core SM G.652.D Black

Nexans ref. N174.517

  • Fiber optic type: SM (G.652D)
  • Number of optical fibres: 96
  • Outer Diameter: 13.2 mm
  • Maximum pulling force (IEC 60794-1-2-E1): 3000 N
  • Crush resistance (IEC 60794-1-E3): 3000 N/100mm
  • Mechanical resistance to impacts (IEC 60794-1-E4): 100 impacts of 3N.m
  • Minimum dynamic operating bending radius: 264.0 mm
  • Minimum static operating bending radius: 132 mm

 

Description

Description

Standards

  • Product
    ANSI/TIA-568-C.3
  • Test
    IEC 60332-1; IEC 60332-3 Cat.C; IEC 60793-2-10
  • International
    ISO/IEC 11801

Description and Application
 

Aginode LANmark-OF UC fibre cable is designed for outdoor applications. The construction is suitable for use outdoor for direct burial. It consists of a central strength memeber surrounded by multiple tubes, a corrugated steel tape armour provides mechanical protection, each loose tube can hold up to 12C fibres, the UC can hold up to 12 sub-tubes based on fibre cores. This provides rodent protection and high crush resistance. The cable has a LSZH outer jacket.

Construction
  
Legend accompanying the cross section drawing:

  1. Optical fibres (250 um)
  2. Waterproof gel filling
  3. Loose tube
  4. Glass Yarn
  5. Central Strength Member
  6. Corrugated steel tape armour
  7. LSZH outer jacket with UV resistant additive 

 
Characteristics
 

  • Flame retardant (IEC 60332-1) and fire retardant (IEC 60332-3-24)
  • Designed for termination by splicing
  • Multiple Loose tube design
  • Corrugated steel protection
  • Waterproof structure and UV-resistant
  • Available in Multimode and Singlemode fibre
  • Available from 48/72/96 fibres

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Armour type
Galvanized steel tapes
Outer sheath
LSZH
Sheath colour
Black

Usage characteristics

Usage characteristics

Ambient installation temperature, range
0 ... 40 °C
操作温度范围
-40 ... 70 °C
Storage temperature, range
-40 ... 70 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close