LANmark-OF Tight Buffer LSZH SM G.652.D 48C YELLOW

Description

Description

Standards

  • Product
    ANSI/TIA-568-C.3
  • Test
    IEC 60332-1; IEC 60332-3-24 Cat.C; IEC 60793-2-10
  • International
    ISO/IEC 11801

Description and Application
 Aginode LANmark-OF TB Indoor fibre cable is designed for indoor applications. The fibre cable has 900μm tight buffered fibres with flame sheath around the transmission medium, and the 900µm sheath provides additional protection for the fibres. The cable is coated with aramid yarns as the strength member, and the outermost layer is coated with LSZH jacket. Bend Insensitive OM3/OM4 and SingleMode G.652.D and G.657.A1 are available.

The fibre cable is of a dry structure suitable for horizontal or vertical installation. The fibre cable meets the needs of indoor fire protection and can be installed in ducts.
• Can be installed both vertically or horizontally
• Applicable as standard multimode and singlemode fibre
• Central FRP strength member
• Up to 8 sub tube, each contain 12c fibres
• LSZH Jacket
• Tight buffered fibre for easy stripping

 Construction

 Legend accompanying the cross section drawing for 48-96core OF cable:

  1. 900µm Tight buffered fibre
  2. Aramid yarn
  3. Subunit jacket
  4. Central FRP Strength member
  5. LSZH jacket materials 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Colour
Yellow
Fiber optic type
SM (G.652D)
Number of tube layer 1
4
Strength member
Central FRP

Dimensional characteristics

Dimensional characteristics

Number of optical fibres
48
Outer Diameter
14.8 mm

Mechanical characteristics

Mechanical characteristics

Maximum pulling force (IEC 60794-1-2-E1)
1500 N
Crush resistance (IEC 60794-1-E3)
1000 N/100mm
Mechanical resistance to impacts (IEC 60794-1-E4)
100 impacts of 1 N.m

Usage characteristics

Usage characteristics

Minimum dynamic operating bending radius
296.0 mm
Minimum static operating bending radius
148 mm
操作温度范围
-20 ... 60 °C
Storage temperature, range
-30 ... 70 °C
Installation temperature, range
0 ... 40 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close